Avocent Access Router Cyclades-PR2000 Manuel d'utilisateur Page 37

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 136
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 36
Cyclades-PR2000
37Chapter 4 - Step-by-Step Instructions
Menu
CONFIG=>MULTILINK=>MULTILINK CIRCUIT NUMBER=>ADD/MODIFY INTERFACE
Parameter Example Your Application
Slot N SWAN 1
Type of Interface Main
Time to Activate
Backup After This
Link Goes Down
5
Time to Deactivate
Backup After This
Link Returns
20
FIGURE 4.18 ADDITION OF THE PRIMARY (MAIN) LINK
Menu
CONFIG=>MULTILINK=>MULTILINK CIRCUIT NUMBER=>ADD/MODIFY INTERFACE
Parameter Example Your Application
Slot N SWAN 2
Type of Interface Backup
Time to Activate
Backup After This
Link Goes Down
Zero
, since this link
IS
the backup. (A
backup can itself have a backup, but
this is not done in this example.)
Time to Deactivate
Backup After This
Link Goes Up
Zero
, since this link
IS
the backup.
Cost One. Indicates the relative priority of
this backup link, which is unnecessary
since this example has only one.
FIGURE 4.19 ADDITION OF THE SECONDARY (BACKUP) LINK