Chapter 2: Installation 23
To install the ECMS4000 user station and ECMS4000 transmitter on a network:
1. Connect the ECMS4000 transmitter to the remote workstation. Connect one end of the UTP
cable to the ECMS4000 transmitters RJ-45 connector. Connect the other end of the UTP cable
to the Ethernet network.
2. Connect the ECMS4000 user station to the peripherals. Use a length of UTP cable to connect
the ECMS4000 user station to the Ethernet network via the RJ-45 connector on the rear of the
ECMS4000 user station.
3. Turn on the ECMS4000 user station. A connection will be automatically established with the
remote workstation.
4. Use the serial menu to reconfigure the network settings for the ECMS4000 transmitter.
NOTE: If the ECMS4000 user station and ECMS4000 transmitter are to be located on different subnets,
configure their network settings before you connect to the network.
NOTE: If there are already ECMS4000 transmitters and ECMS4000 user stations operating on the subnet,
configure network settings of the new ECMS4000 transmitter and ECMS4000 user station pair before connecting
them to the network.
5. Use the serial menu to reconfigure the network settings for the ECMS4000 user station.
6. Repeat this procedure for each ECMS4000 transmitter and ECMS4000 user station pair you
wish to install on the network.
To install the Emerge digital extender system on a network in Desktop Mode:
1. Ensure that each ECMS4000 transmitter and ECMS4000 user station has a unique IP address.
2. Using the DM2000 Manager appliances, locate and add the units to the DM2000 Manager
database. For information on how to do this, refer to the Emerge® DM2000 Manager Installer/
User Guide.
Table 2.10: Default Network Settings (ECMS4000 User Station)
Component IP Address Type
Default
Gateway Subnet Mask
ECMS4000
User Station
192.168.13.1 Static 0.0.0.0 255.255.255.0
ECMS4000
Transmitter
192.168.13.2 Static 0.0.0.0 255.255.255.0