Register Range Units Default Description
S24 0-255 1sec 0 Sleep mode inactivity timer.
S29 0-255 10mS 70 Hook flash dial modifier time.
S30 0-255 10Sec 0 Inactivity disconnect timer.
S95 0 Result code control.
Basic modem result codes
There are basic codes the modem will issue in response to processing an AT command. Result codes may be
displayed either in word (V1) or numeric (V0) format by using the Vn command. The Qn command controls if
result codes are issued (Q0) or not issued (Q1). The Xn, Wn commands and register S95 determines which result
code format the modem will display to indicate the type of connection established. There are more than 300
codes. The most commonly used are listed in the table below.
Numeric Verbose Description
0 OK The modem has received and acknowledged the command.
1 CONNECT Connection made at 300bps or extended result codes are off (X0).
2 RING An incoming ring signal has been detected.
3 NO CARRIER This result code reflects either an intended disconnect or a failure to complete a connection.
4 ERROR An invalid command was issued to the modem.
5 CONNECT 1200 Indicates a 1200bps line or DTE connection.
6 NO DIALTONE
7 BUSY The modem has detected a busy tone.
8 NO ANSWER After S7 time has elapsed, the remote server never answered.
10 CONNECT 2400 Line speed or DTE connection at 2400bps.
12 CONNECT 9600 Line speed or DTE connection at 9600bps.
15 CONNECT 14400 Line speed or DTE connection at 14400bps.
16 CONNECT 19200 Line speed or DTE connection at 19200bps.
17 CONNECT 38400 Line speed or DTE connection at 38400bps.
18 CONNECT 57600 Line speed or DTE connection at 57600bps.
Table E.6: Basic Result Code Listing
Digital line guard
The modem has an optional Digital Line Guard Circuit that automatically detects an over current situation on
the Tip and Ring pins. When the modem goes off hook, it will immediately check the current on the Tip and
Ring pins. If the current exceeds 150 mA, the modem will display the “DIGITAL LINE DETECTED” result code
and then go back on hook. The modem will continue to display this result code until normal current is detected
on the Tip and Ring pins during an off hook condition. The DLG feature will protect the modem in case it is
accidentally connected to a Digital Telephone Line.
Sleep mode operation
The modem can be set to enter the low power sleep mode by setting ATS24=n. In this case, “n” is time, in
seconds, that the modem will operate in normal mode with no detected telephone line or DTE line activity
before entering low power sleep mode. The timer is reset upon any DTE or telephone line activity. If S24 is set
to zero, the modem will never enter the low power sleep mode.