Avocent MERGEPOINT 53XX SP MANAGER Guide de l'utilisateur Page 178

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 236
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 177
show
subtargets
Checking fans on managed servers
You can check fan data on managed servers using the show command with the
/admin1/system[n]/fan[n] target.
To check fan data on an managed server:
Enter the show command followed by the /admin1/system[n]/fan[n] target.
/admin1-> show /system3/fan1
/system3/fan1
properties
CreationClassName = AVCT_Fan
SystemName = 172.26.25.122
SystemCreationClassName = 172.26.25.122:AVCT_Fan
DeviceID = 32:0:48
RequestedState = 5 (No Change)
ActiveCooling = true
EnabledState = 5 (Not Applicable)
HealthState = 0 (Unknown)
OperationalStatus =
VariableSpeed = false
ElementName = FAN 1A RPM
DesiredSpeed = 0
verbs
cd
show
subtargets
Showing console redirection to an service processor
The target for the console of the service processor on a managed server is:
/admin1/system1/textredirectsap[n]. Supported commands are show, start and stop.
To start a console redirection to an service processor:
Enter the start command followed by /admin1/system1/textredirectsap[n].
/admin1/system1-> start textredirectsap1
Booting 'Red Hat Enterprise Linux ES (2.6.9-5.ELsmp)'
root (hd0,1)
166 MergePoin SP Manager Installer/User Guide