Page 1 - AutoView

Installer/User GuideAutoView® 1000RAutoView® 2000R

Page 2

4 AutoView 1000R/ AutoView 2000R Installer/User GuideThe AVRIQ-SRL (serial) module is a DCE device that provides the primary interface between a seri

Page 3

Chapter 1: Product Overview 5 Figure 1.2: Example AutoView 2000R Configuration Safety PrecautionsTo avoid potential video and/or keyboard probl

Page 4 - Agency Approvals

6 AutoView 1000R/ AutoView 2000R Installer/User GuideRack mount safety considerations• Elevated Ambient Temperature: If installed in a closed rack

Page 5 - Table of Contents

ContentsGetting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Rack Mounting Your AutoView 1000R/2000R . . . 10Installing the A

Page 7 - Product Overview

Chapter 2: Installation 9 Chapter 2: InstallationThe AutoView 1000R/2000R appliance requires that the AVWorks software be installed prior to use.

Page 8

10 AutoView 1000R/ AutoView 2000R Installer/User GuideSetting up your networkThe AutoView 1000R/2000R appliance uses IP addresses to uniquely identif

Page 9 - Chapter 1: Product Overview

Chapter 2: Installation 11 Installing the AutoView 1000R/2000RFigure 2.2 illustrates one possible configuration for your AutoView 1000R/2000R appl

Page 10

12 AutoView 1000R/ AutoView 2000R Installer/User GuideCAUTION: To reduce the risk of electric shock or damage to your equipment -- Do not disable the

Page 11 - Safety Precautions

Chapter 2: Installation 13 2. Select option 1 from the Network Confi guration menu to set your network speed. When possible, you should set your c

Page 12 - UTP cables

INSTRUCTIONSThis symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatu

Page 13 - Installation

14 AutoView 1000R/ AutoView 2000R Installer/User GuideTo connect an AVRIQ module to each server:1. Locate the AVRIQ modules for your AutoView 1000R/

Page 14

Chapter 2: Installation 15 5. Connect the other end of the CAT 5 cable to the appropriate AVRIQ module for the server you want to connect to the

Page 15 - Chapter 2: Installation

16 AutoView 1000R/ AutoView 2000R Installer/User GuideTo add a legacy KVM switch:1. Mount the legacy switch into your rack cabinet. Locate a length

Page 16 - Setting up your network

ContentsControlling Your System at the Local Port . . . . . . 19Viewing and Selecting Ports and Servers . . . . . . . . 19Navigating OSCAR . . . . .

Page 18

Chapter 3: Local Port Operation 19 Chapter 3: Local Port OperationControlling Your System at the Local PortThe AutoView 1000R/2000R includes a l

Page 19 - Windows

20 AutoView 1000R/ AutoView 2000R Installer/User GuideViewing the status of your appliance The status of the servers in your system is indicated i

Page 20 - To connect an AVRIQ-PEM:

Chapter 3: Local Port Operation 21 To select the previous server:Press Print Screen and then Backspace. This key combination toggles you betwee

Page 21 - Legacy Switch Support

22 AutoView 1000R/ AutoView 2000R Installer/User GuideOSCAR Navigation Basics (continued) This Keystroke Does ThisEscape Closes the current d

Page 22 - Adding Servers

Chapter 3: Local Port Operation 23 Setup Features to Confi gure OSCARFeature PurposeMenu Change the server listing between numerically by por

Page 23 - Local Port Operation

AutoView® 1000RAutoView® 2000R Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AutoView, AVWorks, Outlook and OSCAR are trad

Page 24

24 AutoView 1000R/ AutoView 2000R Installer/User GuideTo access the Names dialog box:1. If OSCAR is not open, press Print Screen. The Main dialog

Page 25

Chapter 3: Local Port Operation 25 5. Click OK in the Names dialog box to save your changes.-or-Click X or press Escape to exit the dialog box

Page 26 - Selecting servers

26 AutoView 1000R/ AutoView 2000R Installer/User GuideTo assign a device type:1. In the Devices dialog box, select the desired port number.2. Clic

Page 27 - Soft switching

Chapter 3: Local Port Operation 27 To choose the default display order of servers:1. Select Name to display servers alphabetically by name.-or-

Page 28 - Configuring OSCAR

28 AutoView 1000R/ AutoView 2000R Installer/User GuideFigure 3.8: Flag Dialog BoxTo determine how the status fl ag is displayed:1. Select Name or

Page 29 - To access the Setup menu:

Chapter 3: Local Port Operation 29 Broadcasting to ServersThe local user can simultaneously control multiple servers in a system, to ensure th

Page 30

30 AutoView 1000R/ AutoView 2000R Installer/User Guide4. Click the Broadcast Enable checkbox to activate broadcasting.5. From the user station,

Page 31 - Assigning Device Types

Chapter 3: Local Port Operation 31 To remove a server from the scan list:1. In the Scan dialog box, deselect the checkbox next to the server

Page 32 - To assign a device type:

32 AutoView 1000R/ AutoView 2000R Installer/User GuideSetting Console Security OSCAR enables you to set security on your local port console. You

Page 33 - Controlling the Status Flag

Chapter 3: Local Port Operation 33 3. Type the number of minutes for Inactivity Time (from 1-99) to delay activation of password protection and

Page 34 - Figure 3.9: Position Flag

USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user&apos

Page 35 - Broadcasting to Servers

34 AutoView 1000R/ AutoView 2000R Installer/User GuideCAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant wit

Page 36 - Using Scan Mode

Chapter 3: Local Port Operation 35 See Appendix E for information on emulating certain Sun keys using a PS/2 keyboard and special considerations

Page 37 - To cancel scan mode:

36 AutoView 1000R/ AutoView 2000R Installer/User GuideFigure 3.15: Commands Dialog BoxViewing and Disconnecting User ConnectionsYou can view and d

Page 38 - Setting Console Security

Chapter 3: Local Port Operation 37 Figure 3.16: User Status Dialog Box To disconnect a user:1. If OSCAR is not open, press Print Screen. The

Page 39 - NERGY STAR

38 AutoView 1000R/ AutoView 2000R Installer/User Guidereceive a warning indicating that all users (remote and local) will be disconnected. Click OK t

Page 40

Chapter 3: Local Port Operation 39 Figure 3.18: Diagnostics Dialog Box5. As each test is fi nished, a pass or fail symbol appears. The test is co

Page 41

40 AutoView 1000R/ AutoView 2000R Installer/User GuideNOTE: This function is for Microsoft Windows-based computers only. Resetting the PS/2 on a comp

Page 42 - To access the Commands menu:

Chapter 3: Local Port Operation 41 Figure 3.21: Digital Version Dialog Box 4. Click AVRIQ (see Figure 3.20) to view individual AVRIQ version in

Page 43 - Running System Diagnostics

42 AutoView 1000R/ AutoView 2000R Installer/User Guide

Page 44 - To run diagnostic tests:

ContentsConfiguring the Terminal Applications Menu . . . 454Terminal Operations

Page 45

Table of ContentsChapter 1: Product OverviewFeatures and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3Safety Precautions . . . . . . .

Page 47

Chapter 4: Terminal Operations 45 Chapter 4: Terminal OperationsEach individual AutoView 1000R/2000R may be configured at the appliance level th

Page 48

46 AutoView 1000R/ AutoView 2000R Installer/User GuideEnable Debug MessagesThis menu option allows you to configure the AutoView 1000R/2000R to di

Page 49 - Terminal Operations

ContentsAppendix A: FLASH Upgrades . . . . . . . . . . . . . . . . 49Appendix B: Using AVRIQ-SRL Modules . . . . . . . 53Appendix C: Unshielded Twi

Page 51

Appendices 49 AppendicesAppendix A: FLASH UpgradesThe AVRIQ is unavailable while an upgrade is in progress. When an upgrade is initiated, any cur

Page 52 - To change the password:

50 AutoView 1000R/ AutoView 2000R Installer/User Guided. Select TCP/IP protocol.e. Select Properties and note the IP address.6. Assign the IP

Page 53 - Appendices

Appendices 51 Figure A.1: AVRIQ Status Dialog Box 3. Select one or more types of modules to upgrade. Click Upgrade.NOTE: If your AVRIQ module

Page 54

52 AutoView 1000R/ AutoView 2000R Installer/User Guide Figure A.6: AVRIQ Load Dialog Box 6. Click OK to initiate the upgrade and return to the AVR

Page 55

Appendices 53 Appendix B: Using AVRIQ-SRL ModulesThe AVRIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be viewe

Page 57

54 AutoView 1000R/ AutoView 2000R Installer/User Guide• AVR/CD Mode - This option allows you to control how the AutoView 1000R/2000R and CD lines op

Page 58

Appendices 55 • History Key Sequence - This option allows you to defi ne the key combina-tion that enables History mode. The default key sequence

Page 59 - Configuring the AVRIQ-SRL

56 AutoView 1000R/ AutoView 2000R Installer/User Guide5. Repeat steps 3 and 4 to confi gure additional macros.6. When fi nished, press Enter to return

Page 60

Appendices 57 AVRIQ-SRL pinoutsThe following table lists the pinouts for the AVRIQ-SRL module and is provided for your reference.AVRIQ-SRL Pinouts

Page 61 - Creating an AVRIQ-SRL macro

58 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix C: Unshielded Twisted Pair(UTP) CablingThe following information is intended to brief

Page 62 - Using History mode

Appendices 59 AutoView 1000R/2000R Wiring Standards (continued)Pin EIA/TIA 568A EIA/TIA 568B7 white/brown white/brown8 brown brownCabling insta

Page 63 - AVRIQ-SRL Pinouts

60 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix D: Technical Specifications AutoView 1000R/2000R Product Specifi cations Server Ports

Page 64 - UTP copper cabling

Appendices 61 AutoView 1000R/2000R Product Specifi cationsDimensions (continued) Temperature غ-40º Celsius (32º-104º Fahrenheit) operating-20º-

Page 65 - 8 brown brown

62 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix E: Sun Advanced Key EmulationCertain keys on a standard Type 5 (US) Sun keyboard can

Page 66

Appendices 63 These key combinations will work with the USB AVRIQ module (if your Sun system comes with a USB port) as well as the Sun AVRIQ modul

Page 67

ContentsFeatures and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . .

Page 68 - Sun Key Emulation

64 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix F: Technical SupportOur Technical Support staff is ready to assist you with any instal

Page 69 - PS/2-to-USB Keyboard Mappings

WARRANTY Avocent International Ltd. warrants to the original retail purchaser that this product is and will be free from defects in materials and work

Page 70 - Appendix F: Technical Support

590-258-002DFor Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031A

Page 72 - For Technical Support:

Chapter 1: Product Overview 3 Chapter 1: Product OverviewFeatures and BenefitsThe Avocent AutoView® 1000R and 2000R model switches combine ana