Installer/User GuideAutoView® 1000RAutoView® 2000R
4 AutoView 1000R/ AutoView 2000R Installer/User GuideThe AVRIQ-SRL (serial) module is a DCE device that provides the primary interface between a seri
Chapter 1: Product Overview 5 Figure 1.2: Example AutoView 2000R Configuration Safety PrecautionsTo avoid potential video and/or keyboard probl
6 AutoView 1000R/ AutoView 2000R Installer/User GuideRack mount safety considerations• Elevated Ambient Temperature: If installed in a closed rack
ContentsGetting Started . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9Rack Mounting Your AutoView 1000R/2000R . . . 10Installing the A
Chapter 2: Installation 9 Chapter 2: InstallationThe AutoView 1000R/2000R appliance requires that the AVWorks software be installed prior to use.
10 AutoView 1000R/ AutoView 2000R Installer/User GuideSetting up your networkThe AutoView 1000R/2000R appliance uses IP addresses to uniquely identif
Chapter 2: Installation 11 Installing the AutoView 1000R/2000RFigure 2.2 illustrates one possible configuration for your AutoView 1000R/2000R appl
12 AutoView 1000R/ AutoView 2000R Installer/User GuideCAUTION: To reduce the risk of electric shock or damage to your equipment -- Do not disable the
Chapter 2: Installation 13 2. Select option 1 from the Network Confi guration menu to set your network speed. When possible, you should set your c
INSTRUCTIONSThis symbol is intended to alert the user to the presence of important operating and maintenance (servicing) instructions in the literatu
14 AutoView 1000R/ AutoView 2000R Installer/User GuideTo connect an AVRIQ module to each server:1. Locate the AVRIQ modules for your AutoView 1000R/
Chapter 2: Installation 15 5. Connect the other end of the CAT 5 cable to the appropriate AVRIQ module for the server you want to connect to the
16 AutoView 1000R/ AutoView 2000R Installer/User GuideTo add a legacy KVM switch:1. Mount the legacy switch into your rack cabinet. Locate a length
ContentsControlling Your System at the Local Port . . . . . . 19Viewing and Selecting Ports and Servers . . . . . . . . 19Navigating OSCAR . . . . .
Chapter 3: Local Port Operation 19 Chapter 3: Local Port OperationControlling Your System at the Local PortThe AutoView 1000R/2000R includes a l
20 AutoView 1000R/ AutoView 2000R Installer/User GuideViewing the status of your appliance The status of the servers in your system is indicated i
Chapter 3: Local Port Operation 21 To select the previous server:Press Print Screen and then Backspace. This key combination toggles you betwee
22 AutoView 1000R/ AutoView 2000R Installer/User GuideOSCAR Navigation Basics (continued) This Keystroke Does ThisEscape Closes the current d
Chapter 3: Local Port Operation 23 Setup Features to Confi gure OSCARFeature PurposeMenu Change the server listing between numerically by por
AutoView® 1000RAutoView® 2000R Installer/User Guide Avocent, the Avocent logo, The Power of Being There, AutoView, AVWorks, Outlook and OSCAR are trad
24 AutoView 1000R/ AutoView 2000R Installer/User GuideTo access the Names dialog box:1. If OSCAR is not open, press Print Screen. The Main dialog
Chapter 3: Local Port Operation 25 5. Click OK in the Names dialog box to save your changes.-or-Click X or press Escape to exit the dialog box
26 AutoView 1000R/ AutoView 2000R Installer/User GuideTo assign a device type:1. In the Devices dialog box, select the desired port number.2. Clic
Chapter 3: Local Port Operation 27 To choose the default display order of servers:1. Select Name to display servers alphabetically by name.-or-
28 AutoView 1000R/ AutoView 2000R Installer/User GuideFigure 3.8: Flag Dialog BoxTo determine how the status fl ag is displayed:1. Select Name or
Chapter 3: Local Port Operation 29 Broadcasting to ServersThe local user can simultaneously control multiple servers in a system, to ensure th
30 AutoView 1000R/ AutoView 2000R Installer/User Guide4. Click the Broadcast Enable checkbox to activate broadcasting.5. From the user station,
Chapter 3: Local Port Operation 31 To remove a server from the scan list:1. In the Scan dialog box, deselect the checkbox next to the server
32 AutoView 1000R/ AutoView 2000R Installer/User GuideSetting Console Security OSCAR enables you to set security on your local port console. You
Chapter 3: Local Port Operation 33 3. Type the number of minutes for Inactivity Time (from 1-99) to delay activation of password protection and
USA NotificationWarning: Changes or modifications to this unit not expressly approved by the party responsible for compliance could void the user&apos
34 AutoView 1000R/ AutoView 2000R Installer/User GuideCAUTION: Monitor damage can result from the use of Energy mode with monitors not compliant wit
Chapter 3: Local Port Operation 35 See Appendix E for information on emulating certain Sun keys using a PS/2 keyboard and special considerations
36 AutoView 1000R/ AutoView 2000R Installer/User GuideFigure 3.15: Commands Dialog BoxViewing and Disconnecting User ConnectionsYou can view and d
Chapter 3: Local Port Operation 37 Figure 3.16: User Status Dialog Box To disconnect a user:1. If OSCAR is not open, press Print Screen. The
38 AutoView 1000R/ AutoView 2000R Installer/User Guidereceive a warning indicating that all users (remote and local) will be disconnected. Click OK t
Chapter 3: Local Port Operation 39 Figure 3.18: Diagnostics Dialog Box5. As each test is fi nished, a pass or fail symbol appears. The test is co
40 AutoView 1000R/ AutoView 2000R Installer/User GuideNOTE: This function is for Microsoft Windows-based computers only. Resetting the PS/2 on a comp
Chapter 3: Local Port Operation 41 Figure 3.21: Digital Version Dialog Box 4. Click AVRIQ (see Figure 3.20) to view individual AVRIQ version in
42 AutoView 1000R/ AutoView 2000R Installer/User Guide
ContentsConfiguring the Terminal Applications Menu . . . 454Terminal Operations
Table of ContentsChapter 1: Product OverviewFeatures and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3Safety Precautions . . . . . . .
Chapter 4: Terminal Operations 45 Chapter 4: Terminal OperationsEach individual AutoView 1000R/2000R may be configured at the appliance level th
46 AutoView 1000R/ AutoView 2000R Installer/User GuideEnable Debug MessagesThis menu option allows you to configure the AutoView 1000R/2000R to di
ContentsAppendix A: FLASH Upgrades . . . . . . . . . . . . . . . . 49Appendix B: Using AVRIQ-SRL Modules . . . . . . . 53Appendix C: Unshielded Twi
Appendices 49 AppendicesAppendix A: FLASH UpgradesThe AVRIQ is unavailable while an upgrade is in progress. When an upgrade is initiated, any cur
50 AutoView 1000R/ AutoView 2000R Installer/User Guided. Select TCP/IP protocol.e. Select Properties and note the IP address.6. Assign the IP
Appendices 51 Figure A.1: AVRIQ Status Dialog Box 3. Select one or more types of modules to upgrade. Click Upgrade.NOTE: If your AVRIQ module
52 AutoView 1000R/ AutoView 2000R Installer/User Guide Figure A.6: AVRIQ Load Dialog Box 6. Click OK to initiate the upgrade and return to the AVR
Appendices 53 Appendix B: Using AVRIQ-SRL ModulesThe AVRIQ-SRL module is a serial-to-VGA converter which permits VT100-capable devices to be viewe
54 AutoView 1000R/ AutoView 2000R Installer/User Guide• AVR/CD Mode - This option allows you to control how the AutoView 1000R/2000R and CD lines op
Appendices 55 • History Key Sequence - This option allows you to defi ne the key combina-tion that enables History mode. The default key sequence
56 AutoView 1000R/ AutoView 2000R Installer/User Guide5. Repeat steps 3 and 4 to confi gure additional macros.6. When fi nished, press Enter to return
Appendices 57 AVRIQ-SRL pinoutsThe following table lists the pinouts for the AVRIQ-SRL module and is provided for your reference.AVRIQ-SRL Pinouts
58 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix C: Unshielded Twisted Pair(UTP) CablingThe following information is intended to brief
Appendices 59 AutoView 1000R/2000R Wiring Standards (continued)Pin EIA/TIA 568A EIA/TIA 568B7 white/brown white/brown8 brown brownCabling insta
60 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix D: Technical Specifications AutoView 1000R/2000R Product Specifi cations Server Ports
Appendices 61 AutoView 1000R/2000R Product Specifi cationsDimensions (continued) Temperature غ-40º Celsius (32º-104º Fahrenheit) operating-20º-
62 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix E: Sun Advanced Key EmulationCertain keys on a standard Type 5 (US) Sun keyboard can
Appendices 63 These key combinations will work with the USB AVRIQ module (if your Sun system comes with a USB port) as well as the Sun AVRIQ modul
ContentsFeatures and Benefits . . . . . . . . . . . . . . . . . . . . . . . . . 3 Safety Precautions . . . . . . . . . . . . . . . . . . . . . . . .
64 AutoView 1000R/ AutoView 2000R Installer/User GuideAppendix F: Technical SupportOur Technical Support staff is ready to assist you with any instal
WARRANTY Avocent International Ltd. warrants to the original retail purchaser that this product is and will be free from defects in materials and work
590-258-002DFor Technical Support: Avocent Corporation4991 Corporate DriveHuntsville, Alabama 35805-6201 USATel: +1 256 430 4000 Fax: +1 256 430 4031A
Chapter 1: Product Overview 3 Chapter 1: Product OverviewFeatures and BenefitsThe Avocent AutoView® 1000R and 2000R model switches combine ana
Commentaires sur ces manuels